Nissan Altima (L32) 2007-2012 Service Manual: The fuel gauge pointer does not move

Description

Fuel gauge needle will not move from a certain position.

Diagnosis Procedure

1.CHECK COMBINATION METER INPUT SIGNAL

1. Select “METER/M&A” on CONSULT-III.

2. Using “FUEL METER” of “DATA MONITOR”, compare the monitor value with the fuel gauge reading on the combination meter. Refer to MWI-46, "Component Function Check".

Does monitor value match fuel gauge reading? YES >> GO TO 2

NO >> Replace combination meter. Refer to MWI-176, "Removal and Installation".

2.CHECK FUEL LEVEL SENSOR SIGNAL CIRCUIT

Check the fuel level sensor signal circuit. Refer to MWI-46, "Diagnosis Procedure".

Is the inspection result normal? YES >> GO TO 3

NO >> Repair harness or connector.

3.CHECK FUEL LEVEL SENSOR UNIT

Perform a unit check for the fuel level sensor unit. Refer to MWI-47, "Component Inspection".

Is the inspection result normal? YES >> GO TO 4

NO >> Replace fuel level sensor unit. Refer to FL-6, "Removal and Installation".

4.CHECK FLOAT INTERFERENCE

Check that the float arm does not interfere or bind with any of the components in the fuel tank.

Is the inspection result normal? YES >> Replace combination meter. Refer to MWI-176, "Removal and Installation".

NO >> Repair or replace malfunctioning parts.

    The fuel gauge pointer does not move to "f" when refueling
    Description The fuel gauge needle will not move to “F” position when refueling. Diagnosis Procedure 1.OBSERVE FUEL GAUGE Does it take a long time for the pointer to move to FULL position? YES ...

    Other materials:

    Additional service when removing battery negative terminal
     Description Initial setting is necessary when battery terminal is diconnected. CAUTION: The following specified operations are not performed under the non-initialized condition. • Auto-up operation • Anti-pinch function • Retained power operation  Special Repair Requirem ...

    Satellite radio tuner
    Diagnosis Procedure 1.CHECK FUSES Check that the following fuses are not blown. Are the fuses OK? YES >> GO TO 2 NO >> If fuse is blown, be sure to eliminate cause of malfunction before installing new fuse. 2.POWER SUPPLY CIRCUIT CHECK 1. Turn ignition switch OFF. 2. Discon ...

    Diagnosis and repair work flow
    Work Flow OVERALL SEQUENCE DETAILED FLOW 1.GET INFORMATION FOR SYMPTOM Get the detailed information from the customer about the symptom (the condition and the environment when the incident/malfunction occurred) using the “Diagnostic Work Sheet”. (Refer to EC-22, "Diagnostic Work ...