Nissan Altima 2007-2012 Service Manual: Charging system preliminary inspection

Inspection Procedure

1.CHECK BATTERY TERMINALS CONNECTION

Check if battery terminals are clean and tight.

Is the inspection result normal? YES >> GO TO 2

NO >> Repair battery terminals connection.

2.CHECK FUSE

Check for blown fuse and fusible link.

Is the inspection result normal? YES >> GO TO 3

NO >> Be sure to eliminate cause of malfunction before installing new fuse or fusible link.

3.CHECK GENERATOR GROUND TERMINAL CONNECTION

Check if connector E230 terminal 5 (generator ground harness) is clean and tight.

Is the inspection result normal? YES >> GO TO 4

NO >> Repair connection.

4.CHECK DRIVE BELT TENSION

Check drive belt tension. Refer to CHG-29, "Inspection".

Is the inspection result normal? YES >> Inspection End.

NO >> Repair as needed.

    Power generation voltage variable control system operation inspection
    Inspection Procedure CAUTION: When performing this inspection, always use a charged battery that has completed the battery inspection. (When the charging rate of the battery is low, the respons ...

    Other materials:

    Connecting procedure
    NOTE: The connecting procedure must be performed when the vehicle is stationary. If the vehicle starts moving during the procedure, the procedure will be cancelled. To connect a phone to the Bluetooth® Hands- Free Phone System: 1. Press the SETTING button. 2. Use the TUNE/FOLDER knob to s ...

    P0101 maf sensor
    Description The mass air flow sensor (1) is placed in the stream of intake air. It measures the intake flow rate by measuring a part of the entire intake flow. The mass air flow sensor controls the temperature of the hot wire to a certain amount. The heat generated by the hot wire is reduced as ...

    Environmental factors influence the rate of corrosion
    Moisture Accumulation of sand, dirt and water on the vehicle body underside can accelerate corrosion. Wet floor coverings will not dry completely inside the vehicle and should be removed for drying to avoid floor panel corrosion. Relative humidity Corrosion will be accelerated in areas of ...