Nissan Altima (L32) 2007-2012 Service Manual: Additional service when replacing control unit

 Description

Initial setting is necessary when replacing main power window and door lock/unlock switch.

CAUTION: The following specified operations are not performed under the non-initialized condition.

• Auto-up operation

• Anti-pinch function

• Retained power operation

Special Repair Requirement

INITIALIZATION PROCEDURE

1. Disconnect battery negative terminal or main power window and door lock/unlock switch. Reconnect it after a minute or more.

2. Turn ignition switch ON.

3. Operate power window switch to fully open the window. (This operation is unnecessary if the window is already fully open) 4. Continue pulling the power window switch UP (AUTO-UP operation). Even after glass stops at fully closed position, keep pulling the switch for 4 seconds or more.

5. Inspect anti-pinch function.

CHECK ANTI-PINCH FUNCTION

1. Fully open the door window.

2. Place a piece of wood near fully closed position.

3. Close door glass completely with AUTO-UP.

• Check that glass lowers for approximately 150 mm or 2 seconds without pinching piece of wood and stops.

• Check that glass does not rise when operating the main power window and door lock/unlock switch while lowering.

CAUTION: • Do not check with hands and other part of body because they may be pinched. Do not get pinched.

• Check that AUTO-UP operates before inspection when system initialization is performed.

• It may switch to fail-safe mode if open/close operation is performed continuously. Perform initial setting in that situation. Refer to PWC-229, "Fail Safe".

• Perform initial setting when auto-up operation or anti-pinch function does not operate normally.

• Finish initial setting. Otherwise, next operation cannot be done.

1. Auto-up operation

2. Anti-pinch function

3. Retained power operation when ignition switch is OFF.

    Additional service when removing battery negative terminal
     Description Initial setting is necessary when battery terminal is diconnected. CAUTION: The following specified operations are not performed under the non-initialized condition. • Aut ...

    Other materials:

    Front passenger side power window alone does not operate
    Diagnosis Procedure 1. CHECK POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH RH Check power window and door lock/unlock switch RH. Refer to PWC-308, "FRONT POWER WINDOW SWITCH : Component Function Check". Is the inspection result normal? YES >> GO TO 2 NO >> Repair or repla ...

    ECM branch line circuit
    Diagnosis Procedure INSPECTION PROCEDURE 1.CHECK CONNECTOR 1. Turn the ignition switch OFF. 2. Disconnect the battery cable from the negative terminal. 3. Check the following terminals and connectors for damage, bend and loose connection (unit side and connector side). - ECM - Harnes ...

    Air conditioning cut control
    System Diagram System Description INPUT/OUTPUT SIGNAL CHART *1: This signal is sent to the ECM via the CAN communication line. *2: ECM determines the start signal status by the signals of engine speed and battery voltage. SYSTEM DESCRIPTION This system improves engine operation when t ...