Nissan Altima 2007-2012 Service Manual: BCM (Body control module)
Reference Value
VALUES ON THE DIAGNOSIS TOOL
Terminal Layout
Physical Values
1: Sedan only
2: With LH front window anti-pinch
3: With LH and RH front window anti-pinch
Wiring Diagram-Coupe
Wiring Diagram-Sedan
Fail Safe
DTC Inspection Priority Chart
If some DTCs are displayed at the same time, perform inspections one by one based on the following priority chart.
DTC Index
NOTE:
Details of time display
• CRNT: Displays when there is a malfunction now or after returning to the normal condition until turning ignition switch OFF → ON again.
• 1 - 39: Displayed if any previous malfunction is present when current condition is normal. It increases like 1 → 2 → 3...38 → 39 after returning to the normal condition whenever ignition switch OFF → ON. The counter remains at 39 even if the number of cycles exceeds it. It is counted from 1 again when turning ignition switch OFF → ON after returning to the normal condition if the malfunction is detected again.
ECU diagnosis
...
Sunroof system
Reference Value
TERMINAL LAYOUT
PHYSICAL VALUES
Wiring Diagram — Coupe
Wiring Diagram — Sedan
...
Other materials:
P0452 Evap control system pressure sensor
Description
The EVAP control system pressure sensor detects pressure in the
purge line. The sensor output voltage to the ECM increases as pressure
increases.
DTC Logic
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.PRECONDITIONING
If DTC Confirmation Procedure has been previously condu ...
Operating tips
CAUTION
● Do not use alcohol, benzine or thinner
to clean the camera. This will cause
discoloration. To clean the camera,
wipe with a cloth dampened with a diluted
mild cleaning agent and then wipe
with a dry cloth.
● Do not damage the camera as the monitor
screen may be adversel ...
P0102, p0103 maf sensor
Description
The mass air flow sensor (1) is placed in the stream of intake air. It
measures the intake flow rate by measuring a part of the entire
intake flow. The mass air flow sensor controls the temperature of the
hot wire to a certain amount. The heat generated by the hot wire is
reduced a ...