Nissan Altima 2007-2012 Service Manual: Encoder
DRIVER SIDE
Description
Detects condition of the front power window motor LH operation and transmits to main power window and door lock/unlock switch as pulse signal.
Component Function Check
1. CHECK ENCODER OPERATION
Does front door glass LH perform AUTO open/close operation normally with main power window and door lock/unlock switch? Is the inspection result normal? YES >> Encoder operation is OK.
NO >> Refer to PWC-121, "DRIVER SIDE : Diagnosis Procedure".
Diagnosis Procedure
Encoder Circuit Check
1. CHECK ENCODER OPERATION
1. Connect front power window motor LH.
2. Turn ignition switch ON.
3. Check signal between main power window and door lock/unlock switch connector and ground with oscilloscope.
Is the inspection result normal? YES >> Check intermittent incident. Refer to GI-42, "Intermittent Incident".
NO >> GO TO 2
2. CHECK FRONT POWER WINDOW MOTOR LH POWER SUPPLY
1. Turn ignition switch ON.
2. Check voltage between front power window motor LH connector and ground.
Is the measurement value within the specification? YES >> GO TO 4
NO >> GO TO 3
3. CHECK HARNESS CONTINUITY 1
1. Turn ignition switch OFF.
2. Disconnect main power window and door lock/unlock switch and front power window motor LH.
3. Check continuity between main power window and door lock/ unlock switch connector (A) and front power window motor connector (B).
4. Check continuity between main power window and door lock/unlock switch connector (A) and ground.
Is the inspection result normal? YES >> Replace main power window and door lock/unlock switch. Refer to PWC-186, "Removal and Installation". After that, refer to PWC-123, "DRIVER SIDE : Special Repair Requirement".
NO >> Repair or replace harness.
4. CHECK GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect front power window motor LH.
3. Check continuity between front power window motor LH connector and ground.
Is the inspection result normal? YES >> GO TO 6
NO >> GO TO 5
5. CHECK HARNESS CONTINUITY 2
1. Disconnect main power window and door lock/unlock switch.
2. Check continuity between main power window and door lock/ unlock switch connector (A) and front power window motor LH connector (B).
Is the inspection result normal? YES >> Replace main power window and door lock/unlock switch. Refer to PWC-186, "Removal and Installation". After that, refer to PWC-123, "DRIVER SIDE : Special Repair Requirement".
NO >> Repair or replace harness.
6. CHECK HARNESS CONTINUITY 3
1. Disconnect main power window and door lock/unlock switch.
2. Check continuity between main power window and door lock/ unlock switch connector (A) and front power window motor LH connector (B).
3. Check continuity between main power window and door lock/ unlock switch connector (A) and ground.
Is the inspection result normal? YES >> Replace front power window motor LH. Refer to GW-19, "Removal and Installation". After that, refer to PWC-123, "DRIVER SIDE : Special Repair Requirement".
NO >> Repair or replace harness.
Special Repair Requirement
1. PERFORM INITIALIZATION PROCED
Perform initialization procedure.
Refer to PWC-95, "ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : Special Repair Requirement".
Is the inspection result normal? YES >> Inspection end.
NO >> Check intermittent incident. Refer to GI-42, "Intermittent Incident".
Rear RH
Description
Door glass moves UP/DOWN by receiving the signal from main power window and
door lock/unlock switch or
rear power window switch RH.
Component Function Check
1. CHECK POWER WIND ...
Door switch
Description
Detects door open/close condition and transmits the signal to BCM.
Component Function Check
1. CHECK FRONT DOOR SWITCH INPUT SIGNAL
Check (“DOOR SW-DR” and “DOOR SW-AS”) in ...
Other materials:
ABS branch line circuit
Diagnosis Procedure
INSPECTION PROCEDURE
1.CHECK CONNECTOR
1. Turn the ignition switch OFF.
2. Disconnect the battery cable from the negative terminal.
3. Check the terminals and connectors of the ABS actuator and electric unit
(control unit) for damage, bend
and loose connection (unit ...
Expansion valve
Removal and Installation for Expansion Valve
REMOVAL
1. Discharge the refrigerant. Refer to HA-32, "HFC-134a (R-134a) Service
Procedure".
2. Remove the strut tower bar. Refer to FSU-12, "Exploded View".
3. Remove the upper cowl. Refer to EXT-18, "Removal and Instal ...
BCM (Body control module)
Reference Value
VALUES ON THE DIAGNOSIS TOOL
Terminal Layout
Physical Values
1: Sedan only
2: With LH front window anti-pinch
3: With LH and RH front window anti-pinch
4: With Intelligent Key
5: Without Intelligent Key
Wiring Diagram-Sedan
...