Nissan Altima 2007-2012 Service Manual: Harness connector
Description
HARNESS CONNECTOR (TAB-LOCKING TYPE) • The tab-locking type connectors help prevent accidental looseness or disconnection.
• The tab-locking type connectors are disconnected by pushing or lifting the locking tab(s). Refer to the figure below.
Refer to the next page for description of the slide-locking type connector.
CAUTION: Do not pull the harness or wires when disconnecting the connector.
[Example]
HARNESS CONNECTOR (SLIDE-LOCKING TYPE)
• A new style slide-locking type connector is used on certain systems and components, especially those related to OBD.
• The slide-locking type connectors help prevent incomplete locking and accidental looseness or disconnection.
• The slide-locking type connectors are disconnected by pushing or pulling the slider. Refer to the figure below.
CAUTION: • Do not pull the harness or wires when disconnecting the connector.
• Be careful not to damage the connector support bracket when disconnecting the connector.
[Example]
HARNESS CONNECTOR (LEVER LOCKING TYPE)
• Lever locking type harness connectors are used on certain control units and control modules such as ECM, ABS actuator and electric unit (control unit), etc.
• Lever locking type harness connectors are also used on super multiple junction (SMJ) connectors.
• Always confirm the lever is fully locked in place by moving the lever as far as it will go to ensure full connection.
CAUTION:
• Always confirm the lever is fully released (loosened) before attempting to disconnect or connect these connectors to avoid damage to the connector housing or terminals.
1. Control unit with single lever
A. Fasten
B.Loosen
C.Lever
2. Control unit with dual lever
A. Fasten
B.Loosen
C.Lever
3. SMJ connector
A. Fasten
B.Loosen
C.Lever
HARNESS CONNECTOR (DIRECT-CONNECT SRS COMPONENT TYPE)
• SRS direct-connect type harness connectors are used on certain SRS components such as air bag modules and seat belt pre-tensioners.
• Always pull up to release black locking tab prior to removing connector from SRS components.
• Always push down to lock black locking tab afte4r installing connector to SRS components.n When locked, the black locking tab is level with the connector housing.
CAUTION: • Do not pull the harness or wires when removing connectors from SRS components.
Electrical units location
ENGINE COMPARTMENT
PASSENGER COMPARTMENT
LUGGAGE COMPARTMENT
...
Standardized relay
Description
NORMAL OPEN, NORMAL CLOSED AND MIXED TYPE RELAYS
Relays can mainly be divided into three types: normal open, normal closed and
mixed type relays.
TYPE OF STANDARDIZED RELAYS
...
Other materials:
Relay control system
System Diagram
System Description
IPDM E/R activates the internal control circuit to perform the relay ON-OFF
control according to the input signals
from various sensors and the request signals received from control units via CAN
communication.
CAUTION:
IPDM E/R integrated relays cannot ...
Tow truck towing
Tow Truck Towing
CAUTION:
• Never tow a CVT model with the rear wheels raised and the front wheels on the
ground. This may
cause serious and expensive damage to the transaxle. If it is necessary to tow
the vehicle with the
rear wheels raised, always use towing dollies under the front whe ...
P0137, P0157 HO2S2
Description
The heated oxygen sensor 2, after three way catalyst (manifold),
monitors the oxygen level in the exhaust gas on each bank.
Even if switching characteristics of the air fuel ratio (A/F) sensor 1
are shifted, the air-fuel ratio is controlled to stoichiometric, by the signal