Nissan Altima 2007-2012 Service Manual: Additional service when removing battery negative terminal

 Description

Initial setting is necessary when battery terminal is diconnected. CAUTION: The following specified operations are not performed under the non-initialized condition.

• Auto-up operation

• Anti-pinch function

• Retained power operation

 Special Repair Requirement

INITIALIZATION PROCEDURE

1. Disconnect battery negative terminal or main power window and door lock/unlock switch. Reconnect it after a minute or more.

2. Turn ignition switch ON.

3. Operate power window switch to fully open the window. (This operation is unnecessary if the window is already fully open) 4. Continue pulling the power window switch UP (AUTO-UP operation). Even after glass stops at fully closed position, keep pulling the switch for 4 seconds or more.

5. Inspect anti-pinch function.

CHECK ANTI-PINCH FUNCTION

1. Fully open the door window.

2. Place a piece of wood near fully closed position.

3. Close door glass completely with AUTO-UP.

• Check that glass lowers for approximately 150 mm or 2 seconds without pinching piece of wood and stops.

• Check that glass does not rise when operating the power window main switch while lowering.

CAUTION: • Do not check with hands and other part of body because they may be pinched. Do not get pinched.

• Check that AUTO-UP operates before inspection when system initialization is performed.

• It may switch to fail-safe mode if open/close operation is performed continuously. Perform initial setting in that situation. Refer to PWC-42, "Fail Safe".

• Perform initial setting when auto-up operation or anti-pinch function does not operate normally.

• Finish initial setting. Otherwise, next operation cannot be done.

1. Auto-up operation

2. Anti-pinch function

3. Retained power operation when ignition switch is OFF.

    Additional service when replacing control unit
    Description Initial setting is necessary when replacing main power window and door lock/unlock switch. CAUTION: The following specified operations are not performed under the non-initialized c ...

    Other materials:

    P1554 battery current sensor
    Description The power generation voltage variable control enables fuel consumption to be decreased by reducing the engine load which is caused by the power generation of the generator. The battery current sensor is installed to the battery cable at the negative terminal. The sensor measures t ...

    Rear parcel shelf finisher
    Exploded View 1. High mounted stop lamp 2. Rear parcel shelf finisher 3. Seatback release cover 4. Child anchor cover 5. Seatback latch cover Removal and Installation REMOVAL 1. Remove rear seat cushion. Refer to SE-25, "Removal and Installation" 2. Remove rear lower finis ...

    P2100, P2103 Throttle control motor relay