Nissan Altima 2007-2012 Service Manual: Additional service when removing battery negative terminal

 Description

Initial setting is necessary when battery terminal is diconnected. CAUTION: The following specified operations are not performed under the non-initialized condition.

• Auto-up operation

• Anti-pinch function

• Retained power operation

 Special Repair Requirement

INITIALIZATION PROCEDURE

1. Disconnect battery negative terminal or main power window and door lock/unlock switch. Reconnect it after a minute or more.

2. Turn ignition switch ON.

3. Operate power window switch to fully open the window. (This operation is unnecessary if the window is already fully open) 4. Continue pulling the power window switch UP (AUTO-UP operation). Even after glass stops at fully closed position, keep pulling the switch for 4 seconds or more.

5. Inspect anti-pinch function.

CHECK ANTI-PINCH FUNCTION

1. Fully open the door window.

2. Place a piece of wood near fully closed position.

3. Close door glass completely with AUTO-UP.

• Check that glass lowers for approximately 150 mm or 2 seconds without pinching piece of wood and stops.

• Check that glass does not rise when operating the power window main switch while lowering.

CAUTION: • Do not check with hands and other part of body because they may be pinched. Do not get pinched.

• Check that AUTO-UP operates before inspection when system initialization is performed.

• It may switch to fail-safe mode if open/close operation is performed continuously. Perform initial setting in that situation. Refer to PWC-42, "Fail Safe".

• Perform initial setting when auto-up operation or anti-pinch function does not operate normally.

• Finish initial setting. Otherwise, next operation cannot be done.

1. Auto-up operation

2. Anti-pinch function

3. Retained power operation when ignition switch is OFF.

    Additional service when replacing control unit
    Description Initial setting is necessary when replacing main power window and door lock/unlock switch. CAUTION: The following specified operations are not performed under the non-initialized c ...

    Other materials:

    Anti-pinch system does not operate normally (driver side)
    Diagnosis Procedure 1. PERFORM INITIALIZATION PROCEDURE Perform initialization procedure. Refer to PWC-295, "ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : Special Repair Requirement". Is the inspection result normal? YES >> GO TO 2 NO >> Repair or replace the mal ...

    Bose speaker AMP
     Diagnosis Procedure 1.CHECK FUSE Check that the following fuses of the BOSE speaker amp. are not blown. Are the fuses OK? YES >> GO TO 2 NO >> Be sure to eliminate cause of malfunction before installing new fuse. 2.CHECK POWER SUPPLY CIRCUIT 1. Turn ignition switch OFF. ...

    P0745 line pressure solenoid valve
    Description The pressure control solenoid valve A (line pressure solenoid valve) regulates the oil pump discharge pressure to suit the driving condition in response to a signal sent from the TCM. DTC Logic DTC DETECTION LOGIC DTC CONFIRMATION PROCEDURE NOTE: If “DTC CONFIRMATION PROCED ...