Nissan Altima 2007-2012 Service Manual: Auto operation does not operate but manual operates normally (passenger side)

Diagnosis Procedure

1. PERFORM INITIALIZATION PROCEDURE

Perform initialization procedure.

Refer to PWC-190, "ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : Special Repair Requirement".

Is the inspection result normal? YES >> GO TO 2

NO >> Repair or replace the malfunctioning parts.

2. CHECK ENCODER

Check encoder.

Refer to PWC-208, "PASSENGER SIDE : Component Function Check".

Is the inspection result normal? YES >> Inspection End.

NO >> Check intermittent incident. Refer to GI-42, "Intermittent Incident".

    Auto operation does not operate but manual operates normally (driver side)
    Diagnosis Procedure 1. PERFORM INITIALIZATION PROCEDURE Perform initialization procedure. Refer to PWC-190, "ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : Special Repair Requirement&qu ...

    Power window retained power operation does not operate properly
    Diagnosis Procedure 1. CHECK DOOR SWITCH Check door switch. Refer to PWC-212, "Component Function Check". Is the inspection result normal? YES >> Inspection End. NO >&g ...

    Other materials:

    Symptom diagnosis
    UNBALANCE STEERING WHEEL TURNING FORCE (TORQUE VARIATION) Description • Hard steering when fully turning the steering wheel. • Light steering when driving at a high speed. Diagnosis Procedure 1.CHECK SYSTEM FOR POWER SUPPLY AND GROUND Perform trouble diagnosis for power supply and gro ...

    Door finisher
    Exploded View 1. Mirror cover 2. Front door finisher 3. Step lamp lens 4. Rear door finisher 5. Step lamp/reflector lens (if equipped) 6. Arm rest finisher 7. Rear door power window switch finisher 8. Inside release handle 9. Inside release handle escutcheon 9. Inside release handle esc ...

    P0116 ECT sensor
    Description The engine coolant temperature sensor is used to detect the engine coolant temperature. The sensor modifies a voltage signal from the ECM. The modified signal returns to the ECM as the engine coolant temperature input. The sensor uses a thermistor which is sensitive to the change i ...