Nissan Altima (L32) 2007-2012 Service Manual: Inspection and adjustment

Description and Conditions

DESCRIPTION

The purpose of the operational check is to confirm that the system operates properly.

CONDITIONS: • Engine running and at normal operation temperature.

Operational Check

STEP 1: Check Blower

1. Turn blower control dial clockwise, blower should operate on low speed.

2. Continue turning blower control dial clockwise, and continue checking blower speeds until all speeds are checked.

3. Leave blower on HI speed.

If NG, go to HAC-42, "Diagnosis Procedure".

If OK, continue with next check.

STEP 2: Check Discharge Air

1. Press each mode switch and press DEF ( ) switch.

2. Each mode position indicator should illuminate.

3. Confirm that discharge air comes out according to the air distribution table. Refer to HAC-14, "System Description".

NOTE: Confirm that the compressor clutch is engaged (audio or visual inspection) and intake door is in the FRE ( ) position when the DEF () is selected.

Intake door position is checked in the next step.

If NG, go to HAC-32, "Diagnosis Procedure".

If OK, continue with next check.

STEP 3: Check Recirculation

1. Press REC ( ) switch.

Recirculation indicator should illuminate.

2. Press REC ( ) switch a second time.

3. Listen for intake door position change (you should hear blower sound change slightly).

If NG, go to HAC-35, "Diagnosis Procedure".

If OK, continue with next check.

STEP 4: Check Temperature Decrease

1. Turn the temperature dial counterclockwise to 18°C (60F°).

2. Check for cold air at discharge air outlets.

If NG, go to HAC-84, "Component Function Check".

If OK, continue with next check.

STEP 5: Check Temperature Increase

1. Turn the temperature dial clockwise to 32°C (90°F).

2. Check for hot air at discharge air outlets.

If NG, go to HAC-92, "Component Function Check".

If OK, continue with next check.

STEP 6: Check AUTO Mode

1. Press the AUTO switch.

2. Confirm that the compressor clutch engages (audio or visual inspection).

(Discharge air and blower speed will depend on ambient, in-vehicle and set temperatures.) If NG, go to HAC-61, "Diagnosis Procedure", then if necessary, HAC-46, "Component Function Check".

If all operational checks are OK (symptom can not be duplicated), go to Refer to Service Manual and perform tests as outlined to simulate driving condition environment. If symptom appears, refer to HAC-83, "Symptom Matrix Chart".

Auxiliary Mechanism Trimmers

TEMPERATURE SETTING TRIMMER

The trimmer compensates for differences in range of ±3°C (±6°F) between temperature setting (displayed digitally) and temperature felt by customer.

Operating procedures for this trimmer are as follows: 1. Begin self-diagnosis STEP-5 mode. Refer to HAC-22, "Diagnosis Description".

2. Turn blower control dial clockwise to set system in auxiliary mode.

3. Display shows “61” in auxiliary mechanism. It takes approximately 3 seconds to enable setting operation.

4. Turn temperature control dial (LH) as desired. Temperature will change at a rate of 0.5°C (1.0°F) each time a dial is turned.

NOTE: • A decimal point is not indicated on the display.

• Negative value is displayed on the LH temperature display.

When battery cable is disconnected or battery voltage is below 10 V, trimmer operation is canceled. Temperature set becomes that of initial condition, i.e. 0°C (0°F).

FOOT POSITION SETTING TRIMMER

D/F1 stop position mode can be set.

Operating procedures for this trimmer are as follows: 1. Begin self-diagnosis STEP-5 mode. Refer to HAC-22, "Diagnosis Description".

2. Turn blower control dial clockwise to set system in auxiliary mode.

3. Press the OFF switch for each mode as desired.

When battery cable is disconnected or battery voltage is below 10 V, trimmer operation is canceled. Foot position mode set becomes that of initial condition.

INLET PORT MEMORY FUNCTION

When ignition switch is turned from OFF to ON, inlet port can be set to AUTO or manual.

Operating procedures for this trimmer are as follows: 1. Begin self-diagnosis STEP-5 mode. Refer to HAC-22, "Diagnosis Description".

2. Turn blower control dial clockwise to set system in auxiliary mode.

3. Press REC ( ) switch as desired.

When battery cable is disconnected or battery voltage is below 10 V, memory function is canceled. Memory function set becomes that of initial condition.

    Diagnosis and repair workflow
    Work Flow DETAILED FLOW 1.LISTEN TO CUSTOMER COMPLAINT Listen to customer complaint. Get detailed information about the conditions and environment when the symptom occurs. >> GO TO 2 ...

    Other materials:

    P0181 FTT Sensor
    Description The fuel tank temperature sensor is used to detect the fuel temperature inside the fuel tank. The sensor modifies a voltage signal from the ECM. The modified signal returns to the ECM as the fuel temperature input. The sensor uses a thermistor which is sensitive to the change in te ...

    Door key cylinder switch
    Description Power window main switch detects condition of the door key cylinder and transmits to BCM as the LOCK or UNLOCK signals. Component Function Check 1. CHECK DOOR KEY CYLINDER SWITCH INPUT SIGNAL Check (“KEY CYL LK-SW”, “KEY CYL UN-SW”) in “DATA MONITOR” mode for “POWER ...

    B1209 – b1210 collision detection
    Description DTC B1209 - B1210 COLLISION DETECTION The air bag diagnosis sensor unit will set this DTC if it has detected a collision which has resulted in a frontal or side deployment of one or more air bags or pre-tensioners. If this DTC is detected after a SRS repair, the air bag diagnosis ...