Nissan Altima 2007-2012 Service Manual: M&A branch line circuit

Diagnosis Procedure

INSPECTION PROCEDURE

1.CHECK CONNECTOR

1. Turn the ignition switch OFF.

2. Disconnect the battery cable from the negative terminal.

3. Check the terminals and connectors of the combination meter for damage, bend and loose connection (unit side and connector side).

Is the inspection result normal? YES >> GO TO 2.

NO >> Repair the terminal and connector.

2.CHECK HARNESS FOR OPEN CIRCUIT

1. Disconnect the connector of combination meter.

2. Check the resistance between the combination meter harness connector terminals.

Is the measurement value within the specification? YES >> GO TO 3.

NO >> Repair the combination meter branch line.

3.CHECK POWER SUPPLY AND GROUND CIRCUIT

Check the power supply and the ground circuit of the combination meter. Refer to MWI-43, "COMBINATION METER : Diagnosis Procedure".

Is the inspection result normal? YES (Present error)>>Replace the combination meter. Refer to MWI-176, "Removal and Installation".

YES (Past error)>>Error was detected in the combination meter branch line.

NO >> Repair the power supply and the ground circuit.

    DLC branch line circuit
    Diagnosis Procedure INSPECTION PROCEDURE 1.CHECK CONNECTOR 1. Turn the ignition switch OFF. 2. Disconnect the battery cable from the negative terminal. 3. Check the terminals and connectors o ...

    STRG branch line circuit
    Diagnosis Procedure INSPECTION PROCEDURE 1.CHECK CONNECTOR 1. Turn the ignition switch OFF. 2. Disconnect the battery cable from the negative terminal. 3. Check the terminals and connectors o ...

    Other materials:

    P0443 Evap canister purge volume control solenoid valve
    Description The EVAP canister purge volume control solenoid valve is used to control the flow rate of fuel vapor from the EVAP canister. The EVAP canister purge volume control solenoid valve is moved by ON/OFF pulses from the ECM. The longer the ON pulse, the greater the amount of fuel vapor th ...

    ECM branch line circuit
    Diagnosis Procedure INSPECTION PROCEDURE 1.CHECK CONNECTOR 1. Turn the ignition switch OFF. 2. Disconnect the battery cable from the negative terminal. 3. Check the following terminals and connectors for damage, bend and loose connection (unit side and connector side). - ECM - Harnes ...

    Power steering fluid and lines
    Inspection FLUID LEVEL • Check fluid level with engine stopped. • Make sure that fluid level is between MIN and MAX. • Fluid levels at HOT (A) and COLD (B) are different. Do not confuse them. CAUTION: • The fluid level should not exceed the MAX line. Excessive fluid will caus ...