Nissan Altima 2007-2012 Service Manual: P0447 evap canister vent control valve

Description

The EVAP canister vent control valve is located on the EVAP canister and is used to seal the canister vent.

This solenoid valve responds to signals from the ECM. When the ECM sends an ON signal, the coil in the solenoid valve is energized.

A plunger will then move to seal the canister vent. The ability to seal the vent is necessary for the on board diagnosis of other evaporative emission control system components.

This solenoid valve is used only for diagnosis, and usually remains opened.

When the vent is closed, under normal purge conditions, the evaporative emission control system is depressurized and allows “EVAP Control System” diagnosis.

DTC Logic


DTC Logic

DTC DETECTION LOGIC

DTC CONFIRMATION PROCEDURE


DTC CONFIRMATION PROCEDURE

1.PRECONDITIONING

If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at least 10 seconds before conducting the next test.

TESTING CONDITION: Before performing the following procedure, confirm battery voltage is more than 11V at idle.

>> GO TO 2.

2.PERFORM DTC CONFIRMATION PROCEDURE

1. Start engine and wait at least 8 seconds.

2. Check 1st trip DTC.

Is 1st trip DTC detected? YES >> Go to EC-814, "Diagnosis Procedure".

NO >> INSPECTION END

Diagnosis Procedure

1.INSPECTION START

Do you have CONSULT-III? Do you have CONSULT-III? YES >> GO TO 2.

NO >> GO TO 3.

2.CHECK EVAP CANISTER VENT CONTROL VALVE CIRCUIT

1. Turn ignition switch OFF and then turn ON.


1. Turn ignition switch OFF and then turn ON.

2. Select “VENT CONTROL/V” in “ACTIVE TEST” mode with CONSULT-III.

3. Touch “ON/OFF” on CONSULT-III screen.

4. Check for operating sound of the valve.

Clicking sound should be heard.

Is the inspection result normal? YES >> GO TO 7.

NO >> GO TO 3.

3.CHECK EVAP CANISTER VENT CONTROL VALVE POWER SUPPLY CIRCUIT

1. Turn ignition switch OFF.

2. Disconnect EVAP canister vent control valve harness connector.

3. Turn ignition switch ON.

4. Check the voltage between EVAP canister vent control valve harness connector and ground.


Is the inspection result normal?


Is the inspection result normal? YES >> GO TO 5.

NO >> GO TO 4.

4.DETECT MALFUNCTIONING PART

Check the following.

• Harness connectors E11, F2

• Harness connectors E29, B10

• 15A fuse (No,42) • Harness for open or short between EVAP canister vent control valve and IPDM E/R

>> Repair open circuit or short to ground or short to power in harness or connectors.

5.CHECK EVAP CANISTER VENT CONTROL VALVE OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT

1. Turn ignition switch OFF.

2. Disconnect ECM harness connector.

3. Check the continuity between EVAP canister vent control valve harness connector and ECM harness connector.

4. Also check harness for short to ground and short to power.


4. Also check harness for short to ground and short to power.

Is the inspection result normal? YES >> GO TO 7.

NO >> GO TO 6.

6.DETECT MALFUNCTIONING PART

Check the following.

• Junction block connector E44, E45

• Harness connectors E29, B10

• Harness for open or short between EVAP canister vent control valve and ECM >> Repair open circuit or short to ground or short to power in harness or connectors.

7.CHECK RUBBER TUBE FOR CLOGGING

1. Disconnect rubber tube connected to EVAP canister vent control valve.

2. Check the rubber tube for clogging.

Is the inspection result normal?

YES >> GO TO 8.

NO >> Clean the rubber tube using an air blower.

8.CHECK EVAP CANISTER VENT CONTROL VALVE

Refer to EC-816, "Component Inspection".

Is the inspection result normal? YES >> GO TO 9.

NO >> Replace EVAP canister vent control valve.

9.CHECK INTERMITTENT INCIDENT

Refer to GI-42, "Intermittent Incident".

>> INSPECTION END

Component Inspection

1.CHECK EVAP CANISTER VENT CONTROL VALVE-I

1. Turn ignition switch OFF.

2. Remove EVAP canister vent control valve from EVAP canister.

3. Check portion (A) of EVAP canister vent control valve for being rusted.

Is it rusted? YES >> Replace EVAP canister vent control valve NO >> GO TO 2.

2.CHECK EVAP CANISTER VENT CONTROL VALVE-II


2.CHECK EVAP CANISTER VENT CONTROL VALVE-II

1. Reconnect harness connectors disconnected.


1. Reconnect harness connectors disconnected.

2. Turn ignition switch ON.

3. Perform “VENT CONTROL/V” in “ACTIVE TEST” mode.

4. Check air passage continuity and operation delay time.

Make sure new O-ring is installed properly.


Operation takes less than 1 second.


Operation takes less than 1 second.

Check air passage continuity and operation delay time under the following


Check air passage continuity and operation delay time under the following conditions.

Make sure new O-ring is installed properly.

Operation takes less than 1 second.


Operation takes less than 1 second.

Is the inspection result normal? YES >> INSPECTION END

NO >> Replace EVAP canister vent control valve

3.CHECK EVAP CANISTER VENT CONTROL VALVE-III

1. Clean the air passage [portion (A) to (B)] of EVAP canister vent control


1. Clean the air passage [portion (A) to (B)] of EVAP canister vent control valve using an air blower.

2. Perform “VENT CONTROL/V” in “ACTIVE TEST” mode.

3. Check air passage continuity and operation delay time.

Make sure new O-ring is installed properly.


Operation takes less than 1 second.


Operation takes less than 1 second.

1. Clean the air passage [portion (A) to (B)] of EVAP canister vent


1. Clean the air passage [portion (A) to (B)] of EVAP canister vent control valve using an air blower.

2. Check air passage continuity and operation delay time under the following conditions.

Make sure new O-ring is installed properly.

Operation takes less than 1 second.


Operation takes less than 1 second.

Is the inspection result normal? YES >> INSPECTION END

NO >> GO TO 3.

    P0444, p0445 evap canister purge volume control solenoid valve
    Description The EVAP canister purge volume control solenoid valve uses a ON/ OFF duty to control the flow rate of fuel vapor from the EVAP canister. The EVAP canister purge volume control solenoi ...

    P0448 evap canister vent control valve
    Description The EVAP canister vent control valve is located on the EVAP canister and is used to seal the canister vent. This solenoid valve responds to signals from the ECM. When the ECM sends ...

    Other materials:

    P0550 PSP Sensor
    Description Power steering pressure (PSP) sensor is installed to the power steering high-pressure tube and detects a power steering load. This sensor is a potentiometer which transforms the power steering load into output voltage, and emits the voltage signal to the ECM. The ECM controls ...

    Diagnosis system (meter)
    Diagnosis Description SELF-DIAGNOSIS MODE • Odo/trip meter and information display segment operation can be checked in self-diagnosis mode. • Meters/gauges can be checked in self-diagnosis mode. OPERATION PROCEDURE 1. Turn the ignition switch OFF. 2. While pushing the odo/trip ...

    Stall test
    Inspection and Judgment INSPECTION 1. Inspect the amount of engine oil. Replenish the engine oil if necessary. 2. Drive for about 10 minutes to warm up the vehicle so that the CVT fluid temperature is 50 to 80В°C (122 to 176В°F). Inspect the amount of CVT fluid. Replenish if necessary. ...