Nissan Altima 2007-2012 Service Manual: Passenger side

Description

Detects condition of the front power window motor RH operation and transmits to power window and door lock/unlock switch RH as pulse signal.

Component Function Check

1.CHECK ENCODER OPERATION

Does front door glass RH perform AUTO open/close operation normally when operating power window and door lock/unlock switch RH? Is the inspection result normal? YES >> Encoder operation is OK.

NO >> Refer to PWC-323, "PASSENGER SIDE : Diagnosis Procedure".

Diagnosis Procedure

1. CHECK ENCODER SIGNAL

1. Connect front power window motor RH.

2. Turn ignition switch ON.

3. Check signal between power window and door lock/unlock switch RH connector and ground with oscilloscope.

Is the inspection result normal? YES >> Check intermittent incident. Refer to GI-42, "Intermittent Incident".

NO >> GO TO 2

2. CHECK FRONT POWER WINDOW MOTOR RH POWER SUPPLY

1. Turn ignition switch ON.

2. Check voltage between front power window motor RH connector and ground.

Is the measurement value within the specification? YES >> GO TO 4

NO >> GO TO 3

3. CHECK HARNESS CONTINUITY 1

1. Turn ignition switch OFF.

2. Disconnect power window and door lock/unlock switch RH and front power window motor RH.

3. Check continuity between power window and door lock/unlock switch RH connector (A) and front power window motor RH connector (B).

4. Check continuity between power window and door lock/unlock switch RH connector (A) and ground.

Is the inspection result normal? YES >> Replace power window and door lock/unlock switch RH. Refer to PWC-411, "Removal and Installation".

After that, refer to PWC-309, "FRONT POWER WINDOW SWITCH : Special Repair Requirement".

NO >> Repair or replace harness.

4. CHECK GROUND CIRCUIT

1. Turn ignition switch OFF.

2. Disconnect front power window motor RH.

3. Check continuity between front power window motor RH connector and ground.

Is the inspection result normal? YES >> GO TO 6

NO >> GO TO 5

5. CHECK HARNESS CONTINUITY 2

1. Disconnect power window and door lock/unlock switch RH.

2. Check continuity between power window and door lock/unlock switch RH connector (A) and front power window motor RH connector (B).

Is the inspection result normal? YES >> Replace power window and door lock/unlock switch RH.

Refer to PWC-411, "Removal and Installation". After that, refer to PWC-309, "FRONT POWER WINDOW SWITCH : Special Repair Requirement".

NO >> Repair or replace harness.

6. CHECK HARNESS CONTINUITY 3

1. Disconnect power window and door lock/unlock switch RH.

2. Check continuity between power window and door lock/unlock switch RH connector (A) and front power window motor RH connector (B).

3. Check continuity between power window and door lock/unlock switch RH connector (A) and ground.

Is the inspection result normal? YES >> Replace front power window motor RH. Refer to GW-19, "Removal and Installation". After that, refer to PWC-316, "PASSENGER SIDE : Special Repair Requirement".

NO >> Repair or replace harness.

    Driver side
    Description Detects condition of the front power window motor LH operation and transmits to main power window and door lock/unlock switch as pulse signal. Component Function Check 1. CHECK ENC ...

    Door switch
    Description Detects door open/close condition and transmits the signal to BCM. Component Function Check 1. CHECK FRONT DOOR SWITCH INPUT SIGNAL Check (“DOOR SW-DR” and “DOOR SW-AS”) in ...

    Other materials:

    P0703 stop lamp switch
    Description BCM detects ON/OFF state of the stop lamp switch and transmits the data to the TCM via CAN communication by converting the data to a signal. DTC Logic DTC DETECTION LOGIC DTC CONFIRMATION PROCEDURE CAUTION: Always drive vehicle at a safe speed. NOTE: If “DTC CONFIRMATION P ...

    Power steering fluid
    Inspection FLUID LEVEL • Check fluid level with engine stopped. • Make sure that fluid level is between MIN and MAX. • Fluid levels at HOT (A) and COLD (B) are different. Do not confuse them. CAUTION: • The fluid level should not exceed the MAX line. Excessive fluid will caus ...

    Variable induction air system
    Description Power Valves 1 and 2 The power valves 1 and 2 are installed in intake manifold collector and used to control the suction passage of the variable induction air control system. They are set in the fully closed or fully opened position by the power valve actuators 1 and 2 operated b ...