Nissan Altima 2007-2012 Service Manual: Accelerator pedal released position learning

Description

Accelerator Pedal Released Position Learning is a function of ECM to learn the fully released position of the accelerator pedal by monitoring the accelerator pedal position sensor output signal. It must be performed each time harness connector of accelerator pedal position sensor or ECM is disconnected.

Special Repair Requirement

1.START

1. Make sure that accelerator pedal is fully released.

2. Turn ignition switch ON and wait at least 2 seconds.

3. Turn ignition switch OFF and wait at least 10 seconds.

4. Turn ignition switch ON and wait at least 2 seconds.

5. Turn ignition switch OFF and wait at least 10 seconds.

>> END

    Vin registration
    Description VIN Registration is an operation to registering VIN in ECM. It must be performed each time ECM is replaced. NOTE: Accurate VIN which is registered in ECM may be required for Inspec ...

    Throttle valve closed position learning
    Description Throttle Valve Closed Position Learning is a function of ECM to learn the fully closed position of the throttle valve by monitoring the throttle position sensor output signal. It must ...

    Other materials:

    P0340 CMP sensor (phase)
    Description The camshaft position sensor (PHASE) senses the retraction of camshaft (INT) to identify a particular cylinder. The camshaft position sensor (PHASE) senses the piston position. When the crankshaft position sensor (POS) system becomes inoperative, the camshaft position sensor (PHAS ...

    Driving the vehicle
    CONTINUOUSLY VARIABLE TRANSMISSION (CVT) WARNING ● Do not depress the accelerator pedal while shifting from P (Park) or N (Neutral) to R (Reverse), D (Drive), Ds (Drive Sport) or manual shift mode (if so equipped). Always depress the brake pedal until shifting is completed. Failure to ...

    Oil pressure switch signal circuit
    Description Detects the engine oil pressure and transmits the oil pressure switch signal to the IPDM E/R. Component Function Check 1.COMBINATION METER INPUT SIGNAL 1. Select “METER/M&A” on CONSULT-III. 2. Monitor “OIL W/L” of “DATA MONITOR” while operatin ...