Nissan Altima 2007-2012 Service Manual: Charging system preliminary inspection

Inspection Procedure

1.CHECK BATTERY TERMINALS CONNECTION

Check if battery terminals are clean and tight.

Is the inspection result normal? YES >> GO TO 2

NO >> Repair battery terminals connection.

2.CHECK FUSE

Check for blown fuse and fusible link.

Is the inspection result normal?


Is the inspection result normal? YES >> GO TO 3

NO >> Be sure to eliminate cause of malfunction before installing new fuse or fusible link.

3.CHECK GENERATOR GROUND TERMINAL CONNECTION

Check if connector E230 terminal 5 (generator ground harness) is clean and tight.

Is the inspection result normal? YES >> GO TO 4

NO >> Repair connection.

4.CHECK DRIVE BELT TENSION

Check drive belt tension. Refer to CHG-29, "Inspection".

Is the inspection result normal? YES >> Inspection End.

NO >> Repair as needed.

    Power generation voltage variable control system operation inspection
    Inspection Procedure CAUTION: When performing this inspection, always use a charged battery that has completed the battery inspection. (When the charging rate of the battery is low, the respons ...

    Other materials:

    Vehicle recovery (freeing a stuck vehicle)
    Pulling a stuck vehicle WARNING To avoid vehicle damage, serious personal injury or death when recovering a stuck vehicle: ● Contact a professional towing service to recover the vehicle if you have any questions regarding the recovery procedure. ● Do not use the vehicle tie-down ...

    Fluid cooler cleaning
    Cleaning Whenever an automatic transaxle is repaired, overhauled, or replaced, the CVT fluid cooler mounted in the radiator must be inspected and cleaned. Metal debris and friction material, if present, can be trapped or become deposit in the CVT fluid cooler. This debris can contaminate ...

    P1551, P1552 Battery current sensor
    Description The power generation voltage variable control enables fuel consumption to be decreased by reducing the engine load which is caused by the power generation of the generator. The battery current sensor is installed to the battery cable at the negative terminal. The sensor measures t ...