Nissan Altima 2007-2012 Service Manual: Combination meter

Diagnosis Procedure

1.CHECK FUSES

Check for blown combination meter fuses.

Is the inspection result normal? YES >> GO TO 2

NO >> If fuse is blown, be sure to eliminate cause of malfunction before installing new fuse.

2.POWER SUPPLY CIRCUIT CHECK

1. Disconnect combination meter connector.

2. Check voltage between combination meter harness connector M24 terminals 1, 2, 14 and ground.

Is the inspection result normal? YES >> GO TO 3

NO >> Check harness for open between combination meter and fuse.

3.GROUND CIRCUIT CHECK

1. Turn ignition switch OFF.

2. Check continuity between combination meter harness connector terminals 3, 4, 23 and ground.

Is the inspection result normal? YES >> Inspection End.

NO >> Check ground harness.

    BCM (Body control module)
    Diagnosis Procedure 1. CHECK FUSE AND FUSIBLE LINK Check if the following BCM fuse or fusible link are blown. Is the fuse or fusible link blown? YES >> Replace the blown fuse or fusible li ...

    Other materials:

    Does not operate by key cylinder switch
    Diagnosis Procedure 1. PERFORM INITIALIZATION PROCEDURE Perform initialization procedure. Refer to PWC-190, "ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : Special Repair Requirement". Is the inspection result normal? YES >> GO TO 2 NO >> Repair or replace the ma ...

    Reprogramming a single HomeLink® button
    To reprogram a HomeLink® Universal Transceiver button, complete the following: 1. Press and hold the desired HomeLink® button. DO NOT release the button. 2. The indicator light will begin to flash after 20 seconds. Without releasing the HomeLink® button, proceed with “Programming HomeL ...

    Ground
    Ground Distribution MAIN HARNESS ENGINE ROOM HARNESS FRONT END MODULE HARNESS ENGINE CONTROL HARNESS BODY HARNESS BODY NO. 2 HARNESS HARNESS Harness Layout HOW TO READ HARNESS LAYOUT The following Harness Layouts use a map style grid to help locate connectors on the draw ...