Nissan Altima 2007-2012 Service Manual: Front wiper motor ground circuit

Diagnosis Procedure

1.CHECK FRONT WIPER MOTOR (GND) OPEN CIRCUIT

1. Turn the ignition switch OFF.

2. Disconnect front wiper motor.

3. Check continuity between front wiper motor harness connector and ground.

Does continuity exist? YES >> Front wiper motor ground circuit is normal.

NO >> Repair or replace harness.

    Front wiper auto stop signal circuit
    Component Function Check 1. CHECK FRONT WIPER (AUTO STOP) OPERATION 1. Select "FRONT WIPER STOP" of IPDM E/R DATA MONITOR item. 2. Operate the front wiper. 3. With the front wiper ...

    Front wiper and washer system
    Wiring Diagram-Coupe Wiring Diagram-Sedan ...

    Other materials:

    Diagnosis and repair workflow
    Work Flow DETAILED FLOW 1.LISTEN TO CUSTOMER COMPLAINT Listen to customer complaint. Get detailed information about the conditions and environment when the symptom occurs. >> GO TO 2 2.VERIFY THE SYMPTOM WITH OPERATIONAL CHECK Verify the symptom with operational check. Refer to HAC- ...

    M&A branch line circuit
    Diagnosis Procedure INSPECTION PROCEDURE 1.CHECK CONNECTOR 1. Turn the ignition switch OFF. 2. Disconnect the battery cable from the negative terminal. 3. Check the terminals and connectors of the combination meter for damage, bend and loose connection (unit side and connector side). ...

    B2014 chain of strg-immu
    Description BCM performs the ID verification with the steering lock unit to release the steering. BCM starts the communication with the steering lock unit when Intelligent Key is carried into the passenger compartment and the pushbutton ignition switch is pressed. DTC Logic DTC DETECTION L ...