Nissan Altima 2007-2012 Service Manual: Inspection and adjustment

ECM RE-COMMUNICATING FUNCTION

Description

Performing following procedure can automatically perform re-communication of ECM and BCM, but only when the ECM has been replaced with a new one (*1).

*1: New one means an ECM which has never been energized on-board.

(In this step, initialization procedure by CONSULT-III is not necessary) NOTE: • When registering new Key IDs or replacing the ECM that is not brand new, refer to CONSULT-III Operation Manual.

• If multiple keys are attached to the key holder, separate them before work.

• Distinguish keys with unregistered key ID from those with registered ID.

Special Repair Requirement

1.PERFORM ECM RE-COMMUNICATING FUNCTION

1. Install ECM.

2. Insert the registered Intelligent Key (*2), turn ignition switch to “ON”.

*2: To perform this step, use the key that has been used before performing ECM replacement.

3. Maintain ignition switch in “ON” position for at least 5 seconds.

4. Turn ignition switch to “OFF”.

5. Start engine.

Can engine be started? YES >> Procedure is completed.

NO >> Initialize control unit. Refer to CONSULT-III Operation Manual.

    Pre-inspection for diagnostic
    Basic Inspection The engine start function, door lock function, power distribution system and NATS-IVIS/NMS in the Intelligent Key system are closely related to each other regarding control. Narr ...

    Other materials:

    P0122, P0123 TP sensor
    Description Electric throttle control actuator consists of throttle control motor, throttle position sensor, etc. The throttle position sensor responds to the throttle valve movement. The throttle position sensor has two sensors. These sensors are a kind of potentiometers which transform th ...

    ECU diagnosis
    AIR CONDITIONER CONTROL Reference Value VALUES ON THE DIAGNOSIS TOOL TERMINAL LAYOUT PHYSICAL VALUES Wiring Diagram - Air Conditioner Control (Manual) - Coupe Wiring Diagram - Air Conditioner Control (Manual) - Sedan ...

    P0448 evap canister vent control valve
    Description The EVAP canister vent control valve is located on the EVAP canister and is used to seal the canister vent. This solenoid valve responds to signals from the ECM. When the ECM sends an ON signal, the coil in the solenoid valve is energized. A plunger will then move to seal the c ...