Nissan Altima 2007-2012 Service Manual: P1800 Vias control solenoid valve 1

Description

The VIAS control solenoid valve 1 cuts the intake manifold vacuum signal for power valve 1 control. It responds to ON/OFF signals from the ECM. When the solenoid is OFF, the vacuum signal from the intake manifold is cut. When the ECM sends an ON signal the coil pulls the plunger downward and sends the vacuum signal to the power valve actuator 1.

DTC Logic

DTC DETECTION LOGIC

DTC CONFIRMATION PROCEDURE

1.CONDITIONING

If DTC Confirmation Procedure has been previously conducted, always perform the following before conducting the next test.

1. Turn ignition switch OFF and wait at least 10 seconds.

2. Turn ignition switch ON.

3. Turn ignition switch OFF and wait at least 10 seconds.

TESTING CONDITION: Before performing the following procedure, confirm battery voltage is more than 11 V at idle.

>> GO TO 2.

2.PERFORM DTC CONFIRMATION PROCEDURE

1. Start engine and let it idle for at least 5 seconds.

2. Check 1st trip DTC.

Is 1st trip DTC detected? YES >> Go to EC-1428, "Diagnosis Procedure".

NO >> INSPECTION END

Diagnosis Procedure

1.CHECK VIAS CONTROL SOLENOID VALVE 1 POWER SUPPLY CIRCUIT

1. Turn ignition switch OFF.

2. Disconnect VIAS control solenoid valve 1 harness connector.

3. Turn ignition switch ON.

4. Check the voltage between VIAS control solenoid valve 1 harness connector and ground.

Is the inspection result normal? YES >> GO TO 2.

NO >> Repair open circuit, short to ground or short to power in harness or connectors.

2.CHECK VIAS CONTROL SOLENOID VALVE 1 OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT

1. Turn ignition switch OFF.

2. Disconnect ECM harness connector.

3. Check the continuity between VIAS control solenoid valve 1 harness connector and ECM harness connector.

4. Also check harness for short to ground and short to power.

Is the inspection result normal? YES >> GO TO 3.

NO >> Repair open circuit, short to ground or short to power in harness or connectors.

3.CHECK VIAS CONTROL SOLENOID VALVE 1

Refer to EC-1429, "Component Inspection".

Is the inspection result normal? YES >> GO TO 4.

NO >> Replace VIAS control solenoid valve 1.

4.CHECK INTERMITTENT INCIDENT

Refer to GI-42, "Intermittent Incident".

>> INSPECTION END

Component Inspection

1.CHECK VIAS CONTROL SOLENOID VALVE 1

1. Turn ignition switch OFF.

2. Reconnect all harness connectors disconnected.

3. Disconnect vacuum hoses connected to VIAS control solenoid valve 1.

4. Turn ignition switch ON.

5. Select “VIAS S/V-1” in “ACTIVE TEST” mode with CONSULT-III.

6. Check air passage continuity and operation delay time under the following conditions.

1. Turn ignition switch OFF.

2. Disconnect VIAS control solenoid valve 1 harness connector.

3. Disconnect vacuum hoses connected to VIAS volume control solenoid valve 1.

4. Check air passage continuity and operation delay time under the following conditions.

Is the inspection result normal? YES >> INSPECTION END

NO >> Replace VIAS control solenoid valve 1

    P1720 VSS
    Description ECM receives two vehicle speed signals via the CAN communication line. One is sent from “ABS actuator and electric unit (control unit)” via the combination meter, and the other is ...

    P1801 Vias control solenoid valve 2
    Description The VIAS control solenoid valve 2 cuts the intake manifold vacuum signal for power valve 2 control. It responds to ON/OFF signals from the ECM. When the solenoid is OFF, the vacuum s ...

    Other materials:

    P0643 sensor power supply
    DTC Logic DTC DETECTION LOGIC DTC CONFIRMATION PROCEDURE 1.PRECONDITIONING If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at least 10 seconds before conducting the next test. TESTING CONDITION: Before performing the following proced ...

    P0744 A/T TCC S/V function (lock -up)
    Description This malfunction is detected when the torque converter clutch does not lock-up as instructed by the TCM. This is not only caused by electrical malfunction (circuits open or shorted), but also by mechanical malfunction such as control valve sticking, improper solenoid valve operat ...

    Small children
    Children that are over 1 year old and weigh at least 20 lbs (9 kg) should remain in a rear-facing child restraint as long as possible up to the height or weight limit of the child restraint. Children who outgrow the height or weight limit of the rearfacing child restraint and are at least 1 yea ...