Nissan Altima 2007-2012 Service Manual: Passenger side

 Description

Door glass moves UP/DOWN by receiving the signal from main power window and door lock/unlock switch or power window and door lock/unlock switch RH.

Component Function Check

1. CHECK POWER WINDOW MOTOR CIRCIUT

Does power window motor operate with operating main power window and door lock/unlock switch or power window and door lock/unlock switch RH? Is the inspection result normal? YES >> Power window motor RH is OK.

NO >> Refer to PWC-204, "PASSENGER SIDE : Diagnosis Procedure".

 Diagnosis Procedure

Power Window Motor RH Circuit Check

1. CHECK POWER WINDOW SWITCH RH OUTPUT SIGNAL

1. Disconnect power window motor RH.

2. Turn ignition switch ON.

3. Check voltage between power window motor RH connector and ground.

Is the measurement value within the specification? YES >> GO TO 2

NO >> Replace power window and door lock/unlock switch RH. Refer to PWC-291, "Removal and Installation".

After that, refer to PWC-201, "PASSENGER SIDE : Special Repair Requirement".

2. CHECK HARNESS CONTINUITY

1. Turn ignition switch OFF.

2. Disconnect power window and door lock/unlock switch RH.

3. Check continuity between power window and door lock/unlock switch RH connector (A) and power window motor RH connector (B).

4. Check continuity between power window and door lock/unlock switch RH connector (A) and ground.

Is the inspection result normal? YES >> GO TO 3

NO >> Repair or replace harness.

3. CHECK POWER WINDOW MOTOR RH

Check power window motor RH.

Refer to PWC-205, "PASSENGER SIDE : Component Inspection".

Is the inspection result normal? YES >> Check intermittent incident. Refer to GI-42, "Intermittent Incident".

NO >> Replace power window motor RH. Refer to GW-19, "Removal and Installation". After that, refer to PWC-205, "PASSENGER SIDE : Special Repair Requirement".

Component Inspection

1. CHECK POWER WINDOW MOTOR RH

Does motor operate by connecting the battery voltage directly to power window motor RH?

Is the inspection result normal? YES >> Power window motor RH is OK.

NO >> Replace power window motor RH. Refer to GW-19, "Removal and Installation". After that, refer to PWC-205, "PASSENGER SIDE : Special Repair Requirement".

Special Repair Requirement

1. PERFORM INITIALIZATION PROCEDURE

Perform initialization procedure.

Refer to PWC-190, "ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : Special Repair Requirement".

Is the inspection result normal? YES >> GO TO 2

NO >> Check intermittent incident. Refer to GI-42, "Intermittent Incident".

2. CHECK ANTI-PINCH OPERATION

Check anti-pinch operation.

Refer to PWC-190, "ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : Special Repair Requirement".

Is the inspection result normal? YES >> Inspection End.

NO >> Refer to PWC-208, "PASSENGER SIDE : Component Function Check".

    Driver side
    Description Door glass moves UP/DOWN by receiving the signal from main power window and door lock/unlock switch. Component Function Check 1. CHECK POWER WINDOW MOTOR CIRCUIT Does power window ...

    Encoder
    ...

    Other materials:

    Operating range
    The Intelligent Key functions can only be used when the Intelligent Key is within the specified operating range from the request switch 1 . When the Intelligent Key battery is discharged or strong radio waves are present near the operating location, the Intelligent Key system’s operating ...

    Rear window defogger relay
    Description Power is supplied to the rear window defogger with BCM control. Component Function Check 1. CHECK REAR WINDOW DEFOGGER RELAY POWER SUPPLY CIRCUIT Check that an operation noise of rear window defogger relay [located in fuse block (J/B)] can be heard when turning the rear window de ...

    Diagnosis and repair workflow
    Work Flow OVERALL SEQUENCE • Reference 1··· Refer to AV-289, "CONSULT - III Function (MULTI AV)". • Reference 2··· Refer to AV-424, "Symptom Table". DETAILED FLOW 1.CHECK SYMPTOM Check the malfunction symptoms by performing the following items. • Intervie ...